MGN 681 (M) Amendment 1 sets out the UK Maritime and Coastguard Agency’s guidance for handling, storing and charging lithium-ion batteries used in small electric craft aboard yachts. It addresses garage spaces, charging cabinets, monitoring, fire protection and off-gas management. From 1 January 2027, its Type Approval provision applies to relevant battery storage and charging containers placed aboard UK-registered vessels.
What changed in MGN 681 Amendment 1?
The Maritime and Coastguard Agency published Amendment 1 on 19 December 2025 and updated it on 13 January 2026. It gives much clearer direction on the functionality expected of dedicated lithium-ion battery storage and charging cabinets.
The notice was written with yachts operating under Part A of the Red Ensign Group Yacht Code in mind, although its principles may also be useful on other yachts carrying battery-powered personal watercraft. It supplements applicable statutory requirements and class rules; it does not replace them.
The distinction matters. A cabinet suitable for storing a spare battery is not automatically suitable for charging that battery. Charging creates additional demands for electrical control, detection and an effective response if something goes wrong.
Which batteries and vessels does the guidance cover?
The guidance focuses on lithium-ion batteries used in small electric craft and vehicles, including electric tenders, electric jet skis, e-foils and diver propulsion units. Its storage provisions are particularly relevant to removable or spare batteries above 100 Wh.
MGN 681 is not intended to govern a yacht’s main lithium battery propulsion installation. That is a different application with its own rules and guidance. Nor should its provisions be applied automatically to every small consumer device carried on board.
What must a dedicated charging cabinet be capable of?
Sections 4.12 to 4.14 describe the measures relevant where an approved dedicated charging cabinet is used outside the designated garaging space. The cabinet must be appropriately secured and charging supervised. The guidance calls for:
- Charging while the cabinet remains closed.
- Detection and indication of an internal temperature rise.
- Application of a suitable extinguishing medium without opening the cabinet.
- Venting of off-gases to control overpressure and explosive gas accumulation.
- Fire insulation and suitable protection against explosion.
- Automatic interruption of charging when a fault or overheating is detected.
- A clearly defined maximum stored or charged battery capacity in kWh.
For storage, section 4.2 also recognises dedicated cabinets or lockers constructed to certain international standards within the specified spaces. Those storage provisions should not be confused with the additional functionality expected of an approved charging cabinet.
What happens on 1 January 2027?
Section 5.1 states that battery storage and charging containers or boxes placed on board UK-registered vessels from 1 January 2027 must be UK Type Approved and certified by a UK Nominated Body under the framework described in the notice.
Containers already aboard before that date may remain in service, although the MCA recommends replacing them with appropriately approved and certified equipment when possible. This is not a universal Type Approval deadline for every yacht, irrespective of flag or location. Owners should check their flag, class and survey requirements.
Where does RAMBSS fit?
LiVault announced Lloyd’s Register Type Approval for its RAMBSS marine battery safety system in September 2026. The system combines enclosed charging, temperature and smoke detection, charging shutdown, cooling, gas management, pressure relief and alarm functions within a modular enclosure.
Product Type Approval and vessel installation approval are separate questions. The certificate, its operating limits and the proposed location must be reviewed together. For the specific UK requirement in MGN 681 section 5.1, the applicable UK Nominated Body certification status should be confirmed from the certificate package rather than assumed from the words ‘Type Approval’ alone.
What should captains and technical managers do now?
Start with a current battery inventory: battery models, capacities, chargers and charging locations. Identify which units exceed 100 Wh and which are removable. Check the manufacturer’s instructions, the vessel’s risk assessment and the arrangements for alarms, ventilation and firefighting.
If a charging cabinet is proposed, ask for its tested capacity, approval documentation, operating instructions, installation assumptions and any restrictions on battery type or configuration. A certificate is useful only when it describes the equipment and use case being specified.
Next step
Review your yacht battery inventory with LiVault. Ask for a marine assessment and the RAMBSS Type Approval documentation relevant to your proposed installation.
Related LiVault pages
RAMBSS / RACLAN product overview | Marine solutions | Lithium battery safety
Sources and further reading
UK MCA, MGN 681 (M) Amendment 1 (updated 13 January 2026) | LiVault, Lloyd’s Register Type Approval issued for RAMBSS | LiVault, marine solutions