We have answers to the most popular questions about our products and how they work. If you are still unclear about anything, please just get in touch.
The gases released during lithium-ion battery failure vary depending on battery chemistry, state of charge and failure mode. Consequently, no single gas or VOC sensor can reliably detect all battery failure events.
Some systems rely on off-gas detection to disconnect the charging supply before activating further safety measures. However, thermal runaway is a self-sustaining exothermic reaction that can continue independently of the charging supply and propagate to adjacent cells.
RAMBSS combines optical smoke detection with continuous temperature monitoring to identify indicators of developing battery failure and automatically initiate its integrated safety measures, without relying on specific gas detection or the effectiveness of charger disconnection.
This approach formed part of the independent technical assessment supporting RAMBSS's Lloyd's Register Type Approval.
Detection is only the first step. Effective protection requires an immediate response to manage the thermal event and minimise the risk of propagation.
All systems are equipped with an internal supply of Trident coolant which will spray the battery in a thermal runaway event.
In the portable systems, the cooling agent is fully contained in the box in a non-pressurised system.
The RAMBSS modular system, and additional supply of fresh-water will mix with the cooling agent while filling the modules, completely submerging the batteries.
• RACLAN BOX: 1.75 kWh
• RACLAN SQUARE BOX: 3.5 kWh
• RACLAN SQUARE MARINE BOX: 3.5 kWh
• RAMBSS: 5.2 kWh
All LIVAULT systems are independently tested and certified for explosion resistance up a rated kWh battery capacity.
The RAMBSS system has been issued a Type Approval by Lloyds Register in accordance with MGN 681 Amendment 1. This is satisfies the requirement the MGN that battery and charging containers should have Type Approval after January 2027.
LiVAULT systems are certified to store and charge nickel manganese cobalt oxides (NMC) Lithium-Ion batteries.
LiVAULT systems do not require ducting to the outside as gases are managed by the EXO-filter, however they should be located in areas with good ventilation of 80m3 per hour. Yachts and commercial ships seek should guidance from their registered flag states and classification societies.
No.
EN1447 is a standard for cabinets intended to store flammable liquids and flammable gas.
EN 16121 or EN 16122 are standards for the safety, strength and durability of furniture.
LiVAULT systems are certified by independent institutions to test protocols specifically relevant for lithium battery storage and charging. which test for Fire containment, Explosion Integrity and gas management. For marine applications, they are considered as approved test protocols according to MGN 681 (M) Amendment 1 sections 4.12 and 4.13.
Yes, all LIVAULT systems are stackable. In addition, RAMBSS is a fully modular system, available in three sizes which can be arranged specifically to suits your battery inventory. Send us your inventory and we will help you design an arrangement which we can send in PDF, DWG, or 3D CAD formats.
No. We do not offer gel or gas-based suppression as an alternative to freshwater flooding.
The primary objective is to cool individual battery cells and prevent thermal runaway from spreading to adjacent cells. Gel may suppress visible flames but cannot provide the same internal cell cooling as water. Gas-based systems also lack the sustained cooling required to extract heat from battery cells.
Suppressing flames does not necessarily stop thermal runaway. The reaction can continue, releasing heat and flammable gases that may accumulate and create an explosion risk.
RAMBSS uses freshwater flooding to extract heat and limit thermal runaway propagation. This system has been independently tested and verified by RISE, with its performance forming part of the technical assessment supporting Lloyd’s Register Type Approval.